CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricCartridgeSlotEpEpDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricCartridgeSlotEpEpDn

cucsFabricCartridgeSlotEpEpDn

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricCartridgeSlotEpEpDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.127.1.10

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fabric:CartridgeSlotEp:epDn managed object property

What is cucsFabricCartridgeSlotEpEpDn?

This carries the Dn of the underlying local endpoint object that this cartridge slot (bay) actually represents, letting a management tool resolve this row back to the concrete hardware endpoint it describes. Because the slot row and the local endpoint object are separate entries in UCS's data model, an admin's tooling follows this Dn to jump from the slot-level fabric view over to the equipment-side inventory record for the same physical bay. A value like 'sys/chassis-4/slot-5/board' resolves this fabric row to the equipment-side board object for that slot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.127.1.10
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricCartridgeSlotEpEpDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.127.1.10.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricCartridgeSlotEpEpDn.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricCartridgeSlotEpEpDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.127cucsFabricCartridgeSlotEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.127.1cucsFabricCartridgeSlotEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.127.1.10cucsFabricCartridgeSlotEpEpDnCISCO-UNIFIED-COMPUTING-FABRIC-MIB