CISCO-UNIFIED-COMPUTING-EXTVMM-MIB :: cucsExtvmmUpLinkPPFltAggr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EXTVMM-MIBcucsExtvmmUpLinkPPFltAggr

cucsExtvmmUpLinkPPFltAggr

Module: CISCO-UNIFIED-COMPUTING-EXTVMM-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EXTVMM-MIB::cucsExtvmmUpLinkPPFltAggr

OID (numeric): 1.3.6.1.4.1.9.9.719.1.18.31.1.5

Node type: OBJECT-TYPE

Type: Unsigned64

Access: read-only

Description: Cisco UCS extvmm:UpLinkPP:fltAggr managed object property

What is cucsExtvmmUpLinkPPFltAggr?

This is a 64-bit aggregated fault bitmap summarizing any faults currently raised against this specific uplink port profile. Because VM traffic depends on this uplink mapping being healthy, a nonzero fltAggr here, even before checking the individual faults table, is the fastest single-OID signal that something about this DVS's uplink connectivity to the fabric needs attention. A fltAggr of '0' means no faults are currently active on this profile, whereas a nonzero value would send you to the faults table filtered to this profile's Dn for specifics.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.18.31.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EXTVMM-MIB::cucsExtvmmUpLinkPPFltAggr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.18.31.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EXTVMM-MIB::cucsExtvmmUpLinkPPFltAggr.1

Start monitoring Cisco UCS Manager-managed server domains (VMM integration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EXTVMM-MIB::cucsExtvmmUpLinkPPFltAggr OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed server domains (VMM integration) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.18cucsExtvmmObjectsCISCO-UNIFIED-COMPUTING-EXTVMM-MIB
1.3.6.1.4.1.9.9.719.1.18.31cucsExtvmmUpLinkPPTableCISCO-UNIFIED-COMPUTING-EXTVMM-MIB
1.3.6.1.4.1.9.9.719.1.18.31.1cucsExtvmmUpLinkPPEntryCISCO-UNIFIED-COMPUTING-EXTVMM-MIB
1.3.6.1.4.1.9.9.719.1.18.31.1.5cucsExtvmmUpLinkPPFltAggrCISCO-UNIFIED-COMPUTING-EXTVMM-MIB