CISCO-UNIFIED-COMPUTING-ETHER-MIB :: cucsEtherServerIntFIoPcLocale

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-ETHER-MIBcucsEtherServerIntFIoPcLocale

cucsEtherServerIntFIoPcLocale

Module: CISCO-UNIFIED-COMPUTING-ETHER-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-ETHER-MIB::cucsEtherServerIntFIoPcLocale

OID (numeric): 1.3.6.1.4.1.9.9.719.1.16.18.1.9

Node type: OBJECT-TYPE

Type: CucsEtherInternalPcLocale

Access: read-only

Description: Cisco UCS ether:ServerIntFIoPc:locale managed object property

What is cucsEtherServerIntFIoPcLocale?

This value indicates which fabric side — Fabric Interconnect A or B — this internal port-channel bundle is associated with. It matters on the internal port-channel formed by bundling several server-side backplane links between an I/O Module and a Fabric Interconnect because the bundle, like its individual member links, belongs entirely to one side of UCS's dual-fabric redundancy design. A locale of fabric-A on this port-channel means a failure of fabric interconnect A takes this entire bundle down, while the redundant bundle on the other fabric continues carrying traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.16.18.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-ETHER-MIB::cucsEtherServerIntFIoPcLocale

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.16.18.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-ETHER-MIB::cucsEtherServerIntFIoPcLocale.1

Start monitoring Cisco UCS systems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-ETHER-MIB::cucsEtherServerIntFIoPcLocale OID value, configure state conditions and alerts, and monitor any Cisco UCS systems from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.16cucsEtherObjectsCISCO-UNIFIED-COMPUTING-ETHER-MIB
1.3.6.1.4.1.9.9.719.1.16.18cucsEtherServerIntFIoPcTableCISCO-UNIFIED-COMPUTING-ETHER-MIB
1.3.6.1.4.1.9.9.719.1.16.18.1cucsEtherServerIntFIoPcEntryCISCO-UNIFIED-COMPUTING-ETHER-MIB
1.3.6.1.4.1.9.9.719.1.16.18.1.9cucsEtherServerIntFIoPcLocaleCISCO-UNIFIED-COMPUTING-ETHER-MIB