CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentSystemIOControllerFsmRmtInvErrCode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentSystemIOControllerFsmRmtInvErrCode

cucsEquipmentSystemIOControllerFsmRmtInvErrCode

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSystemIOControllerFsmRmtInvErrCode

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.158.1.39

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:SystemIOController:fsmRmtInvErrCode managed object property

What is cucsEquipmentSystemIOControllerFsmRmtInvErrCode?

This Gauge32 ("fsmRmtInvErrCode") records the numeric error code returned by a remote invocation the FSM workflow made against this SIOC module. An admin escalating a failed SIOC operation to Cisco TAC quotes this specific error code, since it identifies the precise remote-call failure rather than a generic "operation failed" message. A value of 0 indicates no remote invocation error occurred; any nonzero code points to a specific internal failure that TAC can look up.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.158.1.39
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSystemIOControllerFsmRmtInvErrCode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.158.1.39.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSystemIOControllerFsmRmtInvErrCode.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsEquipmentSystemIOControllerFsmRmtInvErrCode.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSystemIOControllerFsmRmtInvErrCode OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.158cucsEquipmentSystemIOControllerTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.158.1cucsEquipmentSystemIOControllerEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.158.1.39cucsEquipmentSystemIOControllerFsmRmtInvErrCodeCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB