cucsEquipmentSwitchCardThermal

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSwitchCardThermal

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.70.1.17

Node type: OBJECT-TYPE

Type: CucsEquipmentSensorThresholdStatus

Access: read-only

Description: Cisco UCS equipment:SwitchCard:thermal managed object property

What is cucsEquipmentSwitchCardThermal?

This enumerated value ("thermal") reports the thermal-sensor threshold status of this switch card. An admin investigating unexplained port flaps or a fan-speed increase on a fabric interconnect checks this per-card thermal status first, since a card running hot is a common precursor to link instability before it triggers a hard fault. A value of "ok" is normal; "major" or "critical" would indicate the card's onboard temperature sensor has crossed a threshold that needs immediate attention.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.70.1.17
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSwitchCardThermal

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.70.1.17.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSwitchCardThermal.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSwitchCardThermal OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.70cucsEquipmentSwitchCardTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.70.1cucsEquipmentSwitchCardEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.70.1.17cucsEquipmentSwitchCardThermalCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB