CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentSwitchCapMinActiveFan

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentSwitchCapMinActiveFan

cucsEquipmentSwitchCapMinActiveFan

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSwitchCapMinActiveFan

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.68.1.24

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:SwitchCap:minActiveFan managed object property

What is cucsEquipmentSwitchCapMinActiveFan?

This Gauge32 ("minActiveFan") reports the minimum number of fan modules that must be operational for the fabric-interconnect model to be considered within its supported thermal operating envelope. A facilities/hardware admin monitoring fan-fault alarms uses this threshold to know how many simultaneous fan failures the switch can tolerate before airflow and cooling margin becomes a real risk to the hardware. A value of 2 would mean at least two fans must be running for the unit to stay within its cooling design, even if it has more fan slots in total.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.68.1.24
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSwitchCapMinActiveFan

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.68.1.24.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSwitchCapMinActiveFan.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSwitchCapMinActiveFan OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.68cucsEquipmentSwitchCapTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.68.1cucsEquipmentSwitchCapEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.68.1.24cucsEquipmentSwitchCapMinActiveFanCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB