CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentStorageEncCapProviderDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentStorageEncCapProviderDn

cucsEquipmentStorageEncCapProviderDn

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageEncCapProviderDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.217.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS equipment:StorageEncCapProvider:dn managed object property

What is cucsEquipmentStorageEncCapProviderDn?

This holds the distinguished name (DN) -- the full hierarchical path -- that UCS Manager assigns to a specific enclosure-services capability-catalog entry object in its internal object tree. Because this object is one entry in UCS Manager's Capability Catalog describing what a specific storage-enclosure management chip (SES provider) supports, the DN is what lets UCS Manager, or any script polling this MIB, address this exact instance rather than a whole class of them, chaining together the chassis/server path segments above it. A representative value looks like sys/capabilities/enc-cap-provider-1, where each slash-separated segment narrows from the physical chassis or server down to this one object.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.217.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageEncCapProviderDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.217.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageEncCapProviderDn.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageEncCapProviderDn OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.217cucsEquipmentStorageEncCapProviderTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.217.1cucsEquipmentStorageEncCapProviderEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.217.1.2cucsEquipmentStorageEncCapProviderDnCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB