CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentStorageControllerConfigStorageBiosMode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentStorageControllerConfigStorageBiosMode

cucsEquipmentStorageControllerConfigStorageBiosMode

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageControllerConfigStorageBiosMode

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.156.1.10

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS equipment:StorageControllerConfig:storageBiosMode managed object property

What is cucsEquipmentStorageControllerConfigStorageBiosMode?

This records the storage BIOS mode -- typically RAID versus pass-through/JBOD -- that this controller configuration record describes. Because the same controller chip behaves very differently to the OS depending on which BIOS mode it's flashed to, this field tells UCS Manager which behavior a service profile referencing this controller should expect. A value of 'raid' means the controller is expected to present virtualized logical volumes; 'jbod' would mean it passes physical drives straight through.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.156.1.10
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageControllerConfigStorageBiosMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.156.1.10.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageControllerConfigStorageBiosMode.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageControllerConfigStorageBiosMode OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.156cucsEquipmentStorageControllerConfigTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.156.1cucsEquipmentStorageControllerConfigEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.156.1.10cucsEquipmentStorageControllerConfigStorageBiosModeCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB