CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentStorageControllerConfigDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentStorageControllerConfigDn

cucsEquipmentStorageControllerConfigDn

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageControllerConfigDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.156.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS equipment:StorageControllerConfig:dn managed object property

What is cucsEquipmentStorageControllerConfigDn?

This holds the distinguished name (DN) -- the full hierarchical path -- that UCS Manager assigns to a specific storage (RAID/HBA) controller hardware-identity record object in its internal object tree. Because this object records the PCI identity and BIOS mode of a specific storage controller model so UCS Manager can match it to the right driver and capability profile, the DN is what lets UCS Manager, or any script polling this MIB, address this exact instance rather than a whole class of them, chaining together the chassis/server path segments above it. A representative value looks like sys/rack-unit-4/board/storage-SAS-1/config, where each slash-separated segment narrows from the physical chassis or server down to this one object.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.156.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageControllerConfigDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.156.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageControllerConfigDn.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentStorageControllerConfigDn OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.156cucsEquipmentStorageControllerConfigTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.156.1cucsEquipmentStorageControllerConfigEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.156.1.2cucsEquipmentStorageControllerConfigDnCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB