CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentSlotArrayPolicyOwner

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentSlotArrayPolicyOwner

cucsEquipmentSlotArrayPolicyOwner

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSlotArrayPolicyOwner

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.66.1.24

Node type: OBJECT-TYPE

Type: CucsPolicyPolicyOwner

Access: read-only

Description: Cisco UCS equipment:SlotArray:policyOwner managed object property

What is cucsEquipmentSlotArrayPolicyOwner?

This indicates who owns the policy settings resolved for this slot-array layout descriptor -- whether they were defined locally in this UCS domain or pushed down from a central management point. Since this object describes how a group of physical slots (drive bays or PCIe slots) on a server or chassis are physically arranged, so UCS Manager's GUI can draw an accurate panel diagram and address the slots correctly, knowing the owner tells an admin whether they can safely edit related settings here in UCS Manager or must instead change them upstream, avoiding an edit that would just be overwritten on the next sync. A value of 'local' means this UCS domain manages the setting itself; 'policy' (owned by UCS Central / a policy manager) means a local change attempt would be rejected or reverted on the next sync.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.66.1.24
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSlotArrayPolicyOwner

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.66.1.24.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSlotArrayPolicyOwner.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSlotArrayPolicyOwner OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.66cucsEquipmentSlotArrayTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.66.1cucsEquipmentSlotArrayEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.66.1.24cucsEquipmentSlotArrayPolicyOwnerCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB