All MIBs › CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB › cucsEquipmentSiocTempStatsRearTempMax
cucsEquipmentSiocTempStatsRearTempMax
Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsRearTempMax
OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.197.1.20
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Cisco UCS equipment:SiocTempStats:rearTempMax managed object property
What is cucsEquipmentSiocTempStatsRearTempMax?
This INTEGER is the highest temperature, in degrees Celsius, that the rear-of-module exhaust sensor recorded during the statistics-collection interval. Because a hot rear-zone reading paired with normal fan speeds elsewhere often points to the chassis's exhaust path itself being blocked, for example by cabling stacked too close to the rear of the rack, an admin diagnosing a SIOC cooling problem checks this specific zone rather than relying only on the SIOC's single roll-up thermal status flag. If the interval's max reads 82 while the current instantaneous reading has settled back near 50, that tells an admin the module hit a brief thermal spike that has since subsided rather than one still ongoing.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.197.1.20 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsRearTempMax
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.197.1.20.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsRearTempMax.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsEquipmentSiocTempStatsRearTempMax.1
Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsRearTempMax OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.15 | cucsEquipmentObjects | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.197 | cucsEquipmentSiocTempStatsTable | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.197.1 | cucsEquipmentSiocTempStatsEntry | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.197.1.20 | cucsEquipmentSiocTempStatsRearTempMax | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |