Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsHistMidTempMax

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.198.1.15

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS equipment:SiocTempStatsHist:midTempMax managed object property

What is cucsEquipmentSiocTempStatsHistMidTempMax?

This INTEGER is the highest temperature, in degrees Celsius, that the mid-module sensor recorded during the statistics-collection interval represented by this archived sample. Because the mid-zone sensor is often the first to show a gradual thermal drift caused by dust buildup inside the module, sometimes days before the front or rear zones move at all, an admin diagnosing a SIOC cooling problem checks this specific zone rather than relying only on the SIOC's single roll-up thermal status flag. If the interval's max reads 70 while the current instantaneous reading has settled back near 44, that tells an admin the module hit a brief thermal spike that has since subsided rather than one still ongoing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.198.1.15
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsHistMidTempMax

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.198.1.15.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsHistMidTempMax.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsHistMidTempMax OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.198cucsEquipmentSiocTempStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.198.1cucsEquipmentSiocTempStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.198.1.15cucsEquipmentSiocTempStatsHistMidTempMaxCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB