CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentSiocTempStatsHistFrontTempAvg

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentSiocTempStatsHistFrontTempAvg

cucsEquipmentSiocTempStatsHistFrontTempAvg

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsHistFrontTempAvg

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.198.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS equipment:SiocTempStatsHist:frontTempAvg managed object property

What is cucsEquipmentSiocTempStatsHistFrontTempAvg?

This INTEGER is the average temperature, in degrees Celsius, that the front-of-module intake sensor recorded over the statistics-collection interval represented by this archived sample. Because a rising front-zone reading with a normal rear-zone reading usually means intake airflow is obstructed, for example by dust or a nearby blocked bay, rather than a fan failure, an admin diagnosing a SIOC cooling problem checks this specific zone rather than relying only on the SIOC's single roll-up thermal status flag. An average holding near 35 across the interval is normal for this zone; a rising average even while individual max readings stay in range would flag a slow thermal drift worth watching.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.198.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsHistFrontTempAvg

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.198.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsHistFrontTempAvg.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSiocTempStatsHistFrontTempAvg OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.198cucsEquipmentSiocTempStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.198.1cucsEquipmentSiocTempStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.198.1.9cucsEquipmentSiocTempStatsHistFrontTempAvgCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB