CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentSharedIOModulePresence

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentSharedIOModulePresence

cucsEquipmentSharedIOModulePresence

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSharedIOModulePresence

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.152.1.29

Node type: OBJECT-TYPE

Type: CucsEquipmentPresence

Access: read-only

Description: Cisco UCS equipment:SharedIOModule:presence managed object property

What is cucsEquipmentSharedIOModulePresence?

This reports whether the SIOC is physically present and inserted in its bay. Because the S3260 has two SIOC bays, this is the value UCS Manager flips to 'missing' the instant a module is pulled, which is what actually drives the chassis's inventory and fault display, independent of whether the module was previously healthy. A value of 'equipped' means the bay is occupied; 'missing' appears immediately after a SIOC is removed for replacement.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.152.1.29
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSharedIOModulePresence

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.152.1.29.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSharedIOModulePresence.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentSharedIOModulePresence OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.152cucsEquipmentSharedIOModuleTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.152.1cucsEquipmentSharedIOModuleEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.152.1.29cucsEquipmentSharedIOModulePresenceCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB