CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentServiceDefServicePhilosophy

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentServiceDefServicePhilosophy

cucsEquipmentServiceDefServicePhilosophy

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentServiceDefServicePhilosophy

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.65.1.9

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS equipment:ServiceDef:servicePhilosophy managed object property

What is cucsEquipmentServiceDefServicePhilosophy?

This describes the servicing approach Cisco defines for the equipment this service definition covers -- broadly, whether it is meant to be serviced concurrently with the system running, or only with the system taken offline. An admin planning a maintenance window uses this to decide whether replacing the covered component (say, a fan tray versus a chassis midplane) can be scheduled during production hours or needs a full outage window. A value indicating a concurrent-service philosophy matches a hot-swappable fan or PSU; a non-concurrent value would apply to a component like a chassis backplane that requires the whole chassis powered down.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.65.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentServiceDefServicePhilosophy

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.65.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentServiceDefServicePhilosophy.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentServiceDefServicePhilosophy OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.65cucsEquipmentServiceDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.65.1cucsEquipmentServiceDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.65.1.9cucsEquipmentServiceDefServicePhilosophyCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB