CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentRackUnitPsuStatsAmbientTemp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentRackUnitPsuStatsAmbientTemp

cucsEquipmentRackUnitPsuStatsAmbientTemp

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentRackUnitPsuStatsAmbientTemp

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.63.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS equipment:RackUnitPsuStats:ambientTemp managed object property

What is cucsEquipmentRackUnitPsuStatsAmbientTemp?

This is the temperature, typically in Celsius, that a sensor near this specific PSU last reported inside a rack-mount server. Because PSU inlet temperature often reflects local airflow more directly than a chassis-wide sensor, a rising AmbientTemp on just one PSU while its sibling PSU stays cooler can point to a blocked vent or a fan issue specific to that side of the chassis rather than a room-level cooling problem. A reading climbing from a normal ~28C toward 45C on one PSU while the room and the other PSU stay steady would be worth investigating before it trips a thermal fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.63.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentRackUnitPsuStatsAmbientTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.63.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentRackUnitPsuStatsAmbientTemp.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentRackUnitPsuStatsAmbientTemp OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.63cucsEquipmentRackUnitPsuStatsTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.63.1cucsEquipmentRackUnitPsuStatsEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.63.1.4cucsEquipmentRackUnitPsuStatsAmbientTempCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB