Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuStatsPsuTemp2

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.60.1.34

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS equipment:PsuStats:psuTemp2 managed object property

What is cucsEquipmentPsuStatsPsuTemp2?

This INTEGER is the most recently measured reading from this PSU's second internal temperature sensor, placed at a different internal location than psuTemp1. Comparing psuTemp2 against psuTemp1 for this same PSU lets an admin tell whether heat is concentrated at one internal stage, suggesting a specific failing component, or rising evenly across the unit, suggesting reduced airflow through the whole PSU. A typical reading might be around 46 degrees Celsius, running a few degrees warmer than psuTemp1 on the same unit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.60.1.34
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuStatsPsuTemp2

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.60.1.34.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuStatsPsuTemp2.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuStatsPsuTemp2 OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.60cucsEquipmentPsuStatsTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.60.1cucsEquipmentPsuStatsEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.60.1.34cucsEquipmentPsuStatsPsuTemp2CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB