CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentPsuStatsHistPsuI2CErrors

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentPsuStatsHistPsuI2CErrors

cucsEquipmentPsuStatsHistPsuI2CErrors

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuStatsHistPsuI2CErrors

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.61.1.37

Node type: OBJECT-TYPE

Type: Unsigned64

Access: read-only

Description: Cisco UCS equipment:PsuStatsHist:PsuI2CErrors managed object property

What is cucsEquipmentPsuStatsHistPsuI2CErrors?

This counter records how many I2C bus communication errors occurred between the chassis management controller and a blade's power supply unit during the archived interval covered by this historical row. I2C is the low-speed management bus the PSU uses to report its own telemetry (voltage, current, temperature) back to UCS, so a rising count here points to a flaky backplane connector or a failing PSU controller rather than an actual power-delivery problem. For instance, seeing PsuI2CErrors jump from 0 to 40 in one interval on a single PSU, while its sibling PSU stays at 0, is a strong hint that specific unit needs reseating or replacement.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.61.1.37
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuStatsHistPsuI2CErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.61.1.37.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuStatsHistPsuI2CErrors.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuStatsHistPsuI2CErrors OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.61cucsEquipmentPsuStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.61.1cucsEquipmentPsuStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.61.1.37cucsEquipmentPsuStatsHistPsuI2CErrorsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB