OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuFsmRmtErrDescr
OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.143.1.10
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS equipment:PsuFsm:rmtErrDescr managed object property
What is cucsEquipmentPsuFsmRmtErrDescr?
This string carries the textual description that accompanies the remote error code reported by the PSU if its FSM workflow failed. This is the human-readable message an admin reads directly, rather than looking up rmtErrCode in a table, to understand why a specific operation against this PSU, like a firmware flash, failed at the hardware level. A value might read 'Device is not responding' if the PSU stopped answering mid-operation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.143.1.10 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuFsmRmtErrDescr
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.143.1.10.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuFsmRmtErrDescr.1
Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentPsuFsmRmtErrDescr OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.15 | cucsEquipmentObjects | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.143 | cucsEquipmentPsuFsmTable | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.143.1 | cucsEquipmentPsuFsmEntry | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.143.1.10 | cucsEquipmentPsuFsmRmtErrDescr | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |