CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentNvmeDefPolicyLevel

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentNvmeDefPolicyLevel

cucsEquipmentNvmeDefPolicyLevel

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNvmeDefPolicyLevel

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.230.1.9

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:NvmeDef:policyLevel managed object property

What is cucsEquipmentNvmeDefPolicyLevel?

This Gauge32 records the policyLevel at which the governing policy behind the hardware-definition record describing the physical NVMe drive-bay and PCI-slot layout a specific server model ships with was resolved — essentially how many levels down UCS Manager's organizational hierarchy it had to walk to find the policy actually applied. An admin comparing two seemingly-identical entries of this type that behave differently can use policyLevel to see whether one inherited straight from the root org while the other picked up an override from a nested sub-org, which explains inconsistent behavior for an NVMe drive-bay hardware definition across different orgs. A value of 0 means the policy came straight from the root org; a value like 2 would mean it was resolved from a sub-org two levels down, e.g. root/storage-org.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.230.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNvmeDefPolicyLevel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.230.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNvmeDefPolicyLevel.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNvmeDefPolicyLevel OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.230cucsEquipmentNvmeDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.230.1cucsEquipmentNvmeDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.230.1.9cucsEquipmentNvmeDefPolicyLevelCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB