CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentNetworkElementFanStatsThresholded

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentNetworkElementFanStatsThresholded

cucsEquipmentNetworkElementFanStatsThresholded

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsThresholded

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.86.1.15

Node type: OBJECT-TYPE

Type: CucsEquipmentNetworkElementFanStatsThresholded

Access: read-only

Description: Cisco UCS equipment:NetworkElementFanStats:thresholded managed object property

What is cucsEquipmentNetworkElementFanStatsThresholded?

This enumerated bitmask reports thresholded — which of this fan's own stats (speed, drivePercentage, etc.) currently have an active high/low threshold crossing. It tells an admin, in one field, exactly which metric on this fan tripped a threshold without having to check speed, drivePercentageMax, and every other stat individually for a crossing. A thresholded value indicating 'speedThresholdLow' would mean this fan's actual speed, not its drive percentage, is the metric currently below its configured minimum.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.86.1.15
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsThresholded

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.86.1.15.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsThresholded.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsEquipmentNetworkElementFanStatsThresholded.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsThresholded OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.86cucsEquipmentNetworkElementFanStatsTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.86.1cucsEquipmentNetworkElementFanStatsEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.86.1.15cucsEquipmentNetworkElementFanStatsThresholdedCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB