CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentNetworkElementFanStatsHistDrivePercentageMax

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentNetworkElementFanStatsHistDrivePercentageMax

cucsEquipmentNetworkElementFanStatsHistDrivePercentageMax

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentageMax

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.87.1.6

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:NetworkElementFanStatsHist:drivePercentageMax managed object property

What is cucsEquipmentNetworkElementFanStatsHistDrivePercentageMax?

This Gauge32 preserves the drivePercentageMax that had been recorded for this fan's sampling interval at the moment this historical sample was archived. Retaining past peak values, not just the current one, lets an admin see whether this fan has hit high drive percentages repeatedly over time or whether today's peak is unprecedented. Seeing an archived drivePercentageMax of 90% recur across several retained samples for the same fan would suggest a recurring, not one-time, thermal event.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.87.1.6
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentageMax

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.87.1.6.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentageMax.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentageMax OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87cucsEquipmentNetworkElementFanStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87.1cucsEquipmentNetworkElementFanStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87.1.6cucsEquipmentNetworkElementFanStatsHistDrivePercentageMaxCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB