CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentNetworkElementFanStatsHistDrivePercentageAvg

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentNetworkElementFanStatsHistDrivePercentageAvg

cucsEquipmentNetworkElementFanStatsHistDrivePercentageAvg

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentageAvg

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.87.1.5

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:NetworkElementFanStatsHist:drivePercentageAvg managed object property

What is cucsEquipmentNetworkElementFanStatsHistDrivePercentageAvg?

This Gauge32 preserves the drivePercentageAvg that had been computed for this fan's current sampling interval at the moment this historical sample was archived. It lets an admin reconstruct what the running average looked like at a specific past point in time, rather than only being able to see today's live average. An archived drivePercentageAvg of 42% from three days ago, compared to today's live average of 65%, would show a real upward trend in this fan's typical load.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.87.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentageAvg

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.87.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentageAvg.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentageAvg OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87cucsEquipmentNetworkElementFanStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87.1cucsEquipmentNetworkElementFanStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87.1.5cucsEquipmentNetworkElementFanStatsHistDrivePercentageAvgCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB