CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentNetworkElementFanStatsHistDrivePercentage

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentNetworkElementFanStatsHistDrivePercentage

cucsEquipmentNetworkElementFanStatsHistDrivePercentage

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentage

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.87.1.4

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:NetworkElementFanStatsHist:drivePercentage managed object property

What is cucsEquipmentNetworkElementFanStatsHistDrivePercentage?

This Gauge32 preserves the drivePercentage value — the fan-drive duty cycle — that was in effect for this Fabric Interconnect fan at the moment this particular historical sample was archived. Because the NetworkElementFanStatsHist table keeps a rolling series of these archived readings, an admin can pull several consecutive samples to see whether this fan's drive percentage was climbing before an eventual fault, rather than only seeing the single current value. A run of archived samples reading 35%, 45%, 60%, 80% would show a fan whose drive climbed steadily over the retained history, not a one-off spike.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.87.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.87.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentage.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDrivePercentage OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87cucsEquipmentNetworkElementFanStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87.1cucsEquipmentNetworkElementFanStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87.1.4cucsEquipmentNetworkElementFanStatsHistDrivePercentageCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB