CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentNetworkElementFanStatsHistDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentNetworkElementFanStatsHistDn

cucsEquipmentNetworkElementFanStatsHistDn

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.87.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS equipment:NetworkElementFanStatsHist:dn managed object property

What is cucsEquipmentNetworkElementFanStatsHistDn?

This holds the dn — the Distinguished Name — of one retained historical sample from the rolling stats-history buffer UCS Manager keeps for a single Fabric Interconnect fan; per the DESCRIPTION it is simply the object's 'dn managed object property,' meaning the full slash-delimited path locating it inside UCS Manager's Management Information Tree. Because a Fabric Interconnect keeps a whole rolling history of samples per fan, this dn's path segment (e.g. a stats-hist index) is the only way to tell which archived sample, out of many for the same physical fan, a given row of data comes from. A real value here might look like 'sys/switch-A/fan-module-1-1/fan-1/stats-hist-1', which is what pins down exactly which instance of this archived Fabric Interconnect fan reading the rest of the row's data describes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.87.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.87.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDn.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsHistDn OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87cucsEquipmentNetworkElementFanStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87.1cucsEquipmentNetworkElementFanStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.87.1.2cucsEquipmentNetworkElementFanStatsHistDnCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB