CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentNetworkElementFanStatsAirflowDirection

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentNetworkElementFanStatsAirflowDirection

cucsEquipmentNetworkElementFanStatsAirflowDirection

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsAirflowDirection

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.86.1.4

Node type: OBJECT-TYPE

Type: CucsEquipmentAirflowDirection

Access: read-only

Description: Cisco UCS equipment:NetworkElementFanStats:airflowDirection managed object property

What is cucsEquipmentNetworkElementFanStatsAirflowDirection?

This enumerated value (CucsEquipmentAirflowDirection) records the airflow direction — for example front-to-back versus back-to-front — currently detected for this Fabric Interconnect fan. Airflow direction has to match the data center's hot-aisle/cold-aisle layout; a fan reporting the wrong direction after a swap is a real, physically-verifiable mismatch that fights the room's cooling design rather than a cosmetic reading. airflowDirection = 'front-to-back' matches Cisco's standard UCS cooling convention; the same field reading 'back-to-front' on the same switch would flag a reversed-airflow fan SKU or a miswired replacement.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.86.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsAirflowDirection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.86.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsAirflowDirection.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentNetworkElementFanStatsAirflowDirection OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.86cucsEquipmentNetworkElementFanStatsTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.86.1cucsEquipmentNetworkElementFanStatsEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.86.1.4cucsEquipmentNetworkElementFanStatsAirflowDirectionCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB