CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwner

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwner

cucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwner

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwner

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.44.1.10

Node type: OBJECT-TYPE

Type: CucsPolicyPolicyOwner

Access: read-only

Description: Cisco UCS equipment:MemoryUnitDiscoveryModifierDef:policyOwner managed object property

What is cucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwner?

This enumerated value reports the policyOwner for the capability-catalog override rule that changes how UCS Manager's hardware-discovery logic classifies or constrains one specific DIMM part during blade inventory — which subsystem actually controls its configuration state (for example local, pending-policy, or policy). Knowing the policyOwner tells an admin whether changing a memory discovery-modifier rule's behavior means editing this object directly or instead means editing the UCS Manager policy that owns it, since a direct edit against a policy-owned object gets silently overwritten on the next resolution pass. A policyOwner of 'policy' here would mean a capability-catalog bundle rather than a hand-edited local override is authoritative, so a direct local edit would not survive the next policy resolution.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.44.1.10
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwner

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.44.1.10.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwner.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwner OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.44cucsEquipmentMemoryUnitDiscoveryModifierDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.44.1cucsEquipmentMemoryUnitDiscoveryModifierDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.44.1.10cucsEquipmentMemoryUnitDiscoveryModifierDefPolicyOwnerCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB