CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocatorLedFsmTry

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocatorLedFsmTry

cucsEquipmentLocatorLedFsmTry

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmTry

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.40.1.15

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:LocatorLed:fsmTry managed object property

What is cucsEquipmentLocatorLedFsmTry?

This read-only object mirrors the `fsmTry` property of the blue beacon/locator LED an admin can switch on remotely to physically find a specific chassis, blade, or rack unit in a data center inside Cisco UCS Manager's internal information model, exposed here as a non-negative gauge value for this locator LED. This gauge counts how many times the current FSM stage acting on this locator LED has been retried. A rising fsmTry count for the locator LED on blade 3 in chassis 2 without the workflow ever completing points to a communication problem between UCS Manager and the endpoint hardware, not a one-off glitch.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.40.1.15
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmTry

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.40.1.15.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmTry.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmTry OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.40cucsEquipmentLocatorLedTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.40.1cucsEquipmentLocatorLedEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.40.1.15cucsEquipmentLocatorLedFsmTryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB