CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocatorLedFsmStageDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocatorLedFsmStageDn

cucsEquipmentLocatorLedFsmStageDn

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmStageDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.112.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS equipment:LocatorLedFsmStage:dn managed object property

What is cucsEquipmentLocatorLedFsmStageDn?

This read-only object mirrors the `dn` property of one individual stage within that locator-LED FSM workflow inside Cisco UCS Manager's internal information model, exposed here as a CucsManagedObjectDn-typed value for this FSM stage. The dn is the full hierarchical path string (distinguished name) UCS Manager assigns to this FSM stage, and it is what an admin uses to map an SNMP-walked row of this table back to the exact physical slot or workflow it describes. For the remote-identify stage of a locator-LED toggle, the dn might read something like sys/chassis-2/blade-3/locator-led/fsm-locate/stage-2, letting a monitoring script join this row against the exact chassis and blade it belongs to.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.112.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmStageDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.112.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmStageDn.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmStageDn OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.112cucsEquipmentLocatorLedFsmStageTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.112.1cucsEquipmentLocatorLedFsmStageEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.112.1.2cucsEquipmentLocatorLedFsmStageDnCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB