CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocatorLedFsmRmtInvErrDescr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocatorLedFsmRmtInvErrDescr

cucsEquipmentLocatorLedFsmRmtInvErrDescr

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmRmtInvErrDescr

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.40.1.10

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS equipment:LocatorLed:fsmRmtInvErrDescr managed object property

What is cucsEquipmentLocatorLedFsmRmtInvErrDescr?

This read-only object mirrors the `fsmRmtInvErrDescr` property of the blue beacon/locator LED an admin can switch on remotely to physically find a specific chassis, blade, or rack unit in a data center inside Cisco UCS Manager's internal information model, exposed here as a text string for this locator LED. This text field carries the human-readable error description that accompanies fsmRmtInvErrCode for this locator LED's background workflow. Rather than just a numeric code, this field would spell out something like 'connection timeout' for the failed remote step behind the locator LED on blade 3 in chassis 2.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.40.1.10
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmRmtInvErrDescr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.40.1.10.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmRmtInvErrDescr.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocatorLedFsmRmtInvErrDescr OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.40cucsEquipmentLocatorLedTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.40.1cucsEquipmentLocatorLedEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.40.1.10cucsEquipmentLocatorLedFsmRmtInvErrDescrCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB