CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocalDiskDefSelfEncryptingDrive

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocalDiskDefSelfEncryptingDrive

cucsEquipmentLocalDiskDefSelfEncryptingDrive

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskDefSelfEncryptingDrive

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.39.1.20

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Cisco UCS equipment:LocalDiskDef:selfEncryptingDrive managed object property

What is cucsEquipmentLocalDiskDefSelfEncryptingDrive?

This read-only object mirrors the `selfEncryptingDrive` property of a catalog definition describing the physical and performance specifications of a supported drive model inside Cisco UCS Manager's internal information model, exposed here as a boolean true/false flag for this drive-model definition. This TruthValue states whether the drive model described by this drive-model definition is a self-encrypting drive (SED) with built-in hardware encryption of data at rest. A security-conscious deployment would specifically require the catalog entry for a 1.2TB 10K-RPM SAS drive to report selfEncryptingDrive=true before that drive model is approved for a policy handling regulated data.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.39.1.20
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskDefSelfEncryptingDrive

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.39.1.20.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskDefSelfEncryptingDrive.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskDefSelfEncryptingDrive OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.39cucsEquipmentLocalDiskDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.39.1cucsEquipmentLocalDiskDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.39.1.20cucsEquipmentLocalDiskDefSelfEncryptingDriveCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB