CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocalDiskDefPolicyOwner

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocalDiskDefPolicyOwner

cucsEquipmentLocalDiskDefPolicyOwner

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskDefPolicyOwner

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.39.1.15

Node type: OBJECT-TYPE

Type: CucsPolicyPolicyOwner

Access: read-only

Description: Cisco UCS equipment:LocalDiskDef:policyOwner managed object property

What is cucsEquipmentLocalDiskDefPolicyOwner?

This read-only object mirrors the `policyOwner` property of a catalog definition describing the physical and performance specifications of a supported drive model inside Cisco UCS Manager's internal information model, exposed here as a CucsPolicyPolicyOwner-typed value for this drive-model definition. The policyOwner records whether this drive-model definition's configuration is owned locally on this UCS domain or inherited from a higher-level policy (for example, when UCS Central manages global policies). If this reports 'local' for the catalog entry for a 1.2TB 10K-RPM SAS drive, an admin knows they can edit the policy directly in UCS Manager rather than needing to change it upstream in UCS Central.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.39.1.15
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskDefPolicyOwner

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.39.1.15.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskDefPolicyOwner.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskDefPolicyOwner OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.39cucsEquipmentLocalDiskDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.39.1cucsEquipmentLocalDiskDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.39.1.15cucsEquipmentLocalDiskDefPolicyOwnerCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB