CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupported

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupported

cucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupported

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupported

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.155.1.4

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Cisco UCS equipment:LocalDiskControllerTypeDef:isFlashLifeLeftSup ported managed object property

What is cucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupported?

This read-only object mirrors the `isFlashLifeLeftSupported` property of a narrower catalog definition that flags one specific capability for a disk-controller type inside Cisco UCS Manager's internal information model, exposed here as a boolean true/false flag for this controller-type feature flag. This TruthValue states whether this controller-type feature flag can report SSD wear-level telemetry -- the percentage of write endurance remaining on a flash drive. If the flag entry for an NVMe RAID controller type reports isFlashLifeLeftSupported=true, UCS Manager can show a 'percentage life left' health metric for SSDs behind that controller instead of leaving wear-out invisible until the drive actually fails.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.155.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupported

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.155.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupported.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupported OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.155cucsEquipmentLocalDiskControllerTypeDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.155.1cucsEquipmentLocalDiskControllerTypeDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.155.1.4cucsEquipmentLocalDiskControllerTypeDefIsFlashLifeLeftSupportedCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB