CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocalDiskControllerDefPolicyOwner

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocalDiskControllerDefPolicyOwner

cucsEquipmentLocalDiskControllerDefPolicyOwner

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerDefPolicyOwner

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.38.1.9

Node type: OBJECT-TYPE

Type: CucsPolicyPolicyOwner

Access: read-only

Description: Cisco UCS equipment:LocalDiskControllerDef:policyOwner managed object property

What is cucsEquipmentLocalDiskControllerDefPolicyOwner?

This read-only object mirrors the `policyOwner` property of a catalog definition describing which storage-management features a particular disk-controller type supports inside Cisco UCS Manager's internal information model, exposed here as a CucsPolicyPolicyOwner-typed value for this disk-controller type definition. The policyOwner records whether this disk-controller type definition's configuration is owned locally on this UCS domain or inherited from a higher-level policy (for example, when UCS Central manages global policies). If this reports 'local' for the definition for a MegaRAID-based SAS controller, an admin knows they can edit the policy directly in UCS Manager rather than needing to change it upstream in UCS Central.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.38.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerDefPolicyOwner

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.38.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerDefPolicyOwner.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerDefPolicyOwner OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.38cucsEquipmentLocalDiskControllerDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.38.1cucsEquipmentLocalDiskControllerDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.38.1.9cucsEquipmentLocalDiskControllerDefPolicyOwnerCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB