CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocalDiskControllerDefIntId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocalDiskControllerDefIntId

cucsEquipmentLocalDiskControllerDefIntId

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerDefIntId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.38.1.6

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS equipment:LocalDiskControllerDef:intId managed object property

What is cucsEquipmentLocalDiskControllerDefIntId?

This read-only object mirrors the `intId` property of a catalog definition describing which storage-management features a particular disk-controller type supports inside Cisco UCS Manager's internal information model, exposed here as a text string for this disk-controller type definition. The intId is an internal, system-generated identifier UCS Manager's database assigns to this disk-controller type definition for its own bookkeeping; it is not something an admin chooses. You would see a value like '4128' here even though nothing in the UCS Manager GUI shows this number -- it only matters internally, for correlating database records tied to the definition for a MegaRAID-based SAS controller.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.38.1.6
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerDefIntId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.38.1.6.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerDefIntId.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerDefIntId OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.38cucsEquipmentLocalDiskControllerDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.38.1cucsEquipmentLocalDiskControllerDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.38.1.6cucsEquipmentLocalDiskControllerDefIntIdCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB