CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocalDiskControllerCapRefIsSupported

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocalDiskControllerCapRefIsSupported

cucsEquipmentLocalDiskControllerCapRefIsSupported

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapRefIsSupported

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.80.1.4

Node type: OBJECT-TYPE

Type: CucsEquipmentIsSupported

Access: read-only

Description: Cisco UCS equipment:LocalDiskControllerCapRef:isSupported managed object property

What is cucsEquipmentLocalDiskControllerCapRefIsSupported?

This read-only object mirrors the `isSupported` property of a reference object linking a specific disk-controller instance to its matching entry in the capability catalog inside Cisco UCS Manager's internal information model, exposed here as a CucsEquipmentIsSupported-typed value for this controller's capability-catalog reference. The isSupported flag states whether the capability described by this controller's capability-catalog reference is actually supported on this specific hardware/firmware combination. If this reports false for the reference tying a rack server's RAID controller to its catalog entry, UCS Manager will grey out or reject the related feature in the GUI even though the underlying hardware is otherwise present.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.80.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapRefIsSupported

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.80.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapRefIsSupported.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapRefIsSupported OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.80cucsEquipmentLocalDiskControllerCapRefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.80.1cucsEquipmentLocalDiskControllerCapRefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.80.1.4cucsEquipmentLocalDiskControllerCapRefIsSupportedCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB