CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentLocalDiskControllerCapProviderContainmentMethod

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentLocalDiskControllerCapProviderContainmentMethod

cucsEquipmentLocalDiskControllerCapProviderContainmentMethod

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapProviderContainmentMethod

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.37.1.19

Node type: OBJECT-TYPE

Type: CucsEquipmentStorageContainmentMethod

Access: read-only

Description: Cisco UCS equipment:LocalDiskControllerCapProvider:containmentMet hod managed object property

What is cucsEquipmentLocalDiskControllerCapProviderContainmentMethod?

This read-only object mirrors the `containmentMethod` property of a capability-catalog provider record that stores the hardware-capability data Cisco ships for a specific RAID/storage-controller model inside Cisco UCS Manager's internal information model, exposed here as a CucsEquipmentStorageContainmentMethod-typed value for this RAID-controller capability-catalog entry. The containmentMethod field reports how the drives managed by the controller described in this RAID-controller capability-catalog entry are physically contained -- for example direct-attached backplane bays versus an external enclosure. For the catalog record covering a 12G SAS RAID controller, a value indicating a backplane-contained method tells an admin the drives live in the server's own front bays rather than an external JBOD.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.37.1.19
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapProviderContainmentMethod

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.37.1.19.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapProviderContainmentMethod.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapProviderContainmentMethod OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.37cucsEquipmentLocalDiskControllerCapProviderTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.37.1cucsEquipmentLocalDiskControllerCapProviderEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.37.1.19cucsEquipmentLocalDiskControllerCapProviderContainmentMethodCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB