All MIBs › CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB › cucsEquipmentLocalDiskControllerCapProviderContainmentMethod
cucsEquipmentLocalDiskControllerCapProviderContainmentMethod
Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapProviderContainmentMethod
OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.37.1.19
Node type: OBJECT-TYPE
Type: CucsEquipmentStorageContainmentMethod
Access: read-only
Description: Cisco UCS equipment:LocalDiskControllerCapProvider:containmentMet hod managed object property
What is cucsEquipmentLocalDiskControllerCapProviderContainmentMethod?
This read-only object mirrors the `containmentMethod` property of a capability-catalog provider record that stores the hardware-capability data Cisco ships for a specific RAID/storage-controller model inside Cisco UCS Manager's internal information model, exposed here as a CucsEquipmentStorageContainmentMethod-typed value for this RAID-controller capability-catalog entry. The containmentMethod field reports how the drives managed by the controller described in this RAID-controller capability-catalog entry are physically contained -- for example direct-attached backplane bays versus an external enclosure. For the catalog record covering a 12G SAS RAID controller, a value indicating a backplane-contained method tells an admin the drives live in the server's own front bays rather than an external JBOD.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.37.1.19 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapProviderContainmentMethod
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.37.1.19.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapProviderContainmentMethod.1
Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentLocalDiskControllerCapProviderContainmentMethod OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.15 | cucsEquipmentObjects | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.37 | cucsEquipmentLocalDiskControllerCapProviderTable | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.37.1 | cucsEquipmentLocalDiskControllerCapProviderEntry | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.37.1.19 | cucsEquipmentLocalDiskControllerCapProviderContainmentMethod | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |