CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentInbandMgmtCapDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentInbandMgmtCapDn

cucsEquipmentInbandMgmtCapDn

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentInbandMgmtCapDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.124.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS equipment:InbandMgmtCap:dn managed object property

What is cucsEquipmentInbandMgmtCapDn?

This read-only object mirrors the `dn` property of a capability record stating whether in-band management -- managing the endpoint over the production data network instead of the dedicated management port -- is supported for a given hardware/firmware combination inside Cisco UCS Manager's internal information model, exposed here as a CucsManagedObjectDn-typed value for this in-band-management capability record. The dn is the full hierarchical path string (distinguished name) UCS Manager assigns to this in-band-management capability record, and it is what an admin uses to map an SNMP-walked row of this table back to the exact physical slot or workflow it describes. For the in-band capability entry tied to a blade's CIMC, the dn might read something like sys/chassis-2/blade-3/mgmt/inband-cap, letting a monitoring script join this row against the exact chassis and blade it belongs to.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.124.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentInbandMgmtCapDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.124.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentInbandMgmtCapDn.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentInbandMgmtCapDn OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.124cucsEquipmentInbandMgmtCapTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.124.1cucsEquipmentInbandMgmtCapEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.124.1.2cucsEquipmentInbandMgmtCapDnCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB