CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentIOExpanderCapProviderLoadErrors

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentIOExpanderCapProviderLoadErrors

cucsEquipmentIOExpanderCapProviderLoadErrors

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentIOExpanderCapProviderLoadErrors

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.211.1.9

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:IOExpanderCapProvider:loadErrors managed object property

What is cucsEquipmentIOExpanderCapProviderLoadErrors?

This read-only object mirrors the `loadErrors` property of a capability-catalog provider record that stores the hardware-capability data Cisco ships (in the capability catalog bundle) for a specific I/O expander model inside Cisco UCS Manager's internal information model, exposed here as a non-negative gauge value for this I/O-expander capability-catalog entry. This gauge counts hard parsing errors UCS Manager hit while loading the capability-catalog section for this I/O-expander capability-catalog entry. A jump in this counter for the catalog record covering a UCS X-Fabric IFM expander right after a catalog upgrade is the first signal an admin should check before trusting any capability data from that entry.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.211.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentIOExpanderCapProviderLoadErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.211.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentIOExpanderCapProviderLoadErrors.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentIOExpanderCapProviderLoadErrors OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.211cucsEquipmentIOExpanderCapProviderTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.211.1cucsEquipmentIOExpanderCapProviderEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.211.1.9cucsEquipmentIOExpanderCapProviderLoadErrorsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB