CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentHDDFaultMonDefControllerFwVersion

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentHDDFaultMonDefControllerFwVersion

cucsEquipmentHDDFaultMonDefControllerFwVersion

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentHDDFaultMonDefControllerFwVersion

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.85.1.4

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS equipment:HDDFaultMonDef:ControllerFwVersion managed object property

What is cucsEquipmentHDDFaultMonDefControllerFwVersion?

This read-only SnmpAdminString field is the 'controllerFwVersion' property of the 'HDDFaultMonDef' managed object in Cisco UCS Manager's equipment-inventory schema giving the RAID/storage controller firmware version this fault-monitoring definition applies to. This scopes the definition to a specific controller firmware level, since the depth of disk health telemetry (like predictive-failure data) a controller can expose often depends on its firmware version. A definition scoped to ControllerFwVersion '24.16.0-0091' might expose disk fault data that an older firmware on the same controller model could not report.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.85.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentHDDFaultMonDefControllerFwVersion

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.85.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentHDDFaultMonDefControllerFwVersion.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentHDDFaultMonDefControllerFwVersion OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.85cucsEquipmentHDDFaultMonDefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.85.1cucsEquipmentHDDFaultMonDefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.85.1.4cucsEquipmentHDDFaultMonDefControllerFwVersionCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB