CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentGraphicsCardCapRefIsSupported

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentGraphicsCardCapRefIsSupported

cucsEquipmentGraphicsCardCapRefIsSupported

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentGraphicsCardCapRefIsSupported

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.119.1.7

Node type: OBJECT-TYPE

Type: CucsEquipmentIsSupported

Access: read-only

Description: Cisco UCS equipment:GraphicsCardCapRef:isSupported managed object property

What is cucsEquipmentGraphicsCardCapRefIsSupported?

This read-only CucsEquipmentIsSupported field is the 'isSupported' property of the 'GraphicsCardCapRef' managed object in Cisco UCS Manager's equipment-inventory schema indicating whether this specific GPU model/revision/vendor combination is validated for the parent server. This is the actual pass/fail verdict UCS Manager surfaces (and can alarm on) when a physically installed GPU doesn't match a combination Cisco has validated for that server model, which is the direct answer to 'will Cisco support me running this GPU in this server' rather than just describing the GPU's own specs. A GraphicsCardCapRef entry reporting IsSupported as false for a given GPU model in a given server chassis would explain why UCS Manager raises an unsupported-hardware fault after that card is installed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.119.1.7
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentGraphicsCardCapRefIsSupported

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.119.1.7.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentGraphicsCardCapRefIsSupported.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentGraphicsCardCapRefIsSupported OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.119cucsEquipmentGraphicsCardCapRefTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.119.1cucsEquipmentGraphicsCardCapRefEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.119.1.7cucsEquipmentGraphicsCardCapRefIsSupportedCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB