CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentFexPsuInputStatsVoltage

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentFexPsuInputStatsVoltage

cucsEquipmentFexPsuInputStatsVoltage

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPsuInputStatsVoltage

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.26.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS equipment:FexPsuInputStats:voltage managed object property

What is cucsEquipmentFexPsuInputStatsVoltage?

This read-only INTEGER field is the 'voltage' property of the 'FexPsuInputStats' managed object in Cisco UCS Manager's equipment-inventory schema for the FEX (Fabric Extender) subsystem reporting the PSU's instantaneous AC/DC input voltage. This is the line voltage the PSU is actually seeing at its input right now, the figure to check first if a PSU starts throwing power faults, since a sagging or fluctuating input voltage is a common root cause. A Voltage reading of 208V is normal for a PSU wired to three-phase 208V facility power; a reading that has dropped to 180V would point to an upstream power-quality problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.26.1.18
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPsuInputStatsVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.26.1.18.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPsuInputStatsVoltage.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPsuInputStatsVoltage OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.26cucsEquipmentFexPsuInputStatsTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.26.1cucsEquipmentFexPsuInputStatsEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.26.1.18cucsEquipmentFexPsuInputStatsVoltageCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB