CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentFexPsuInputStatsInputStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentFexPsuInputStatsInputStatus

cucsEquipmentFexPsuInputStatsInputStatus

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPsuInputStatsInputStatus

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.26.1.8

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS equipment:FexPsuInputStats:inputStatus managed object property

What is cucsEquipmentFexPsuInputStatsInputStatus?

This read-only SnmpAdminString field is the 'inputStatus' property of the 'FexPsuInputStats' managed object in Cisco UCS Manager's equipment-inventory schema for the FEX (Fabric Extender) subsystem reporting the health/state of the PSU's AC/DC input feed. This is the direct readout of whether the PSU is actually receiving good input power at all, so it's the first thing to check before trusting any of the current, voltage, or power numbers from the same PSU, since a bad or missing input feed makes those numbers meaningless. InputStatus reading something like 'no-input' on one PSU while its sibling PSU reads 'ok' points straight at a failed power cord or upstream outlet rather than a PSU hardware fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.26.1.8
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPsuInputStatsInputStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.26.1.8.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPsuInputStatsInputStatus.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPsuInputStatsInputStatus OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.26cucsEquipmentFexPsuInputStatsTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.26.1cucsEquipmentFexPsuInputStatsEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.26.1.8cucsEquipmentFexPsuInputStatsInputStatusCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB