CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentFexPowerSummaryHistReservedPowerMax

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentFexPowerSummaryHistReservedPowerMax

cucsEquipmentFexPowerSummaryHistReservedPowerMax

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPowerSummaryHistReservedPowerMax

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.25.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS equipment:FexPowerSummaryHist:reservedPowerMax managed object property

What is cucsEquipmentFexPowerSummaryHistReservedPowerMax?

This read-only INTEGER field is the 'reservedPowerMax' property of the 'FexPowerSummaryHist' managed object in Cisco UCS Manager's equipment-inventory schema for the FEX (Fabric Extender) subsystem capturing the highest reserved-power commitment seen in the window. The highest reservation seen flags the moment UCS Manager committed the most power specifically to this FEX, which matters if that commitment is starving other gear sharing the same power group. A ReservedPowerMax of 95W would show the FEX's guaranteed slice briefly grew, perhaps right after a new module came online.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.25.1.16
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPowerSummaryHistReservedPowerMax

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.25.1.16.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPowerSummaryHistReservedPowerMax.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsEquipmentFexPowerSummaryHistReservedPowerMax.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPowerSummaryHistReservedPowerMax OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.25cucsEquipmentFexPowerSummaryHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.25.1cucsEquipmentFexPowerSummaryHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.25.1.16cucsEquipmentFexPowerSummaryHistReservedPowerMaxCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB