CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentFexPowerSummaryHistAvailablePower

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentFexPowerSummaryHistAvailablePower

cucsEquipmentFexPowerSummaryHistAvailablePower

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPowerSummaryHistAvailablePower

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.25.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS equipment:FexPowerSummaryHist:availablePower managed object property

What is cucsEquipmentFexPowerSummaryHistAvailablePower?

This read-only INTEGER field is the 'availablePower' property of the 'FexPowerSummaryHist' managed object in Cisco UCS Manager's equipment-inventory schema for the FEX (Fabric Extender) subsystem representing the power still available to the FEX from the fabric interconnect's shared power pool. This is the headroom UCS Manager calculates it can still allocate to the FEX from the shared budget, so a value trending toward zero is the early warning that adding another PSU, blade, or module could trip a power cap. A lightly loaded N2232 FEX might show 150W of AvailablePower, dropping to single digits once several blade slots and their fans are fully populated.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.25.1.8
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPowerSummaryHistAvailablePower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.25.1.8.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPowerSummaryHistAvailablePower.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexPowerSummaryHistAvailablePower OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.25cucsEquipmentFexPowerSummaryHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.25.1cucsEquipmentFexPowerSummaryHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.25.1.8cucsEquipmentFexPowerSummaryHistAvailablePowerCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB