All MIBs › CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB › cucsEquipmentFexEnvStatsHistInlet
cucsEquipmentFexEnvStatsHistInlet
Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexEnvStatsHistInlet
OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.22.1.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Cisco UCS equipment:FexEnvStatsHist:inlet managed object property
What is cucsEquipmentFexEnvStatsHistInlet?
This stores the archived general inlet temperature reading for the FEX at the moment this history row was captured. An admin reviewing this alongside other archived rows can pinpoint exactly when that FEX's intake air started running hotter, which helps correlate a later fault with a real, gradually building environmental cause. A stepped rise across successive rows -- 24, then 31, then 38 -- for the same FEX marks a clear worsening trend.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.22.1.9 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexEnvStatsHistInlet
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.22.1.9.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexEnvStatsHistInlet.1
Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFexEnvStatsHistInlet OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.15 | cucsEquipmentObjects | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.22 | cucsEquipmentFexEnvStatsHistTable | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.22.1 | cucsEquipmentFexEnvStatsHistEntry | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.22.1.9 | cucsEquipmentFexEnvStatsHistInlet | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |