CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentFanStatsHistSpeed

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentFanStatsHistSpeed

cucsEquipmentFanStatsHistSpeed

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanStatsHistSpeed

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.18.1.6

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS equipment:FanStatsHist:speed managed object property

What is cucsEquipmentFanStatsHistSpeed?

This stores the archived rotational speed reading for the fan at the moment this history row was captured. Reviewing a run of these values lets an admin reconstruct a fan's speed behavior leading up to an incident, for example confirming it ramped up gradually versus dropping abruptly. A sequence like 6500, 6600, 6400, then 900 RPM across consecutive history rows for the same fan clearly marks the point where something went wrong.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.18.1.6
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanStatsHistSpeed

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.18.1.6.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanStatsHistSpeed.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanStatsHistSpeed OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.18cucsEquipmentFanStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.18.1cucsEquipmentFanStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.18.1.6cucsEquipmentFanStatsHistSpeedCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB