All MIBs › CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB › cucsEquipmentFanPower
cucsEquipmentFanPower
Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanPower
OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.12.1.12
Node type: OBJECT-TYPE
Type: CucsEquipmentPowerState
Access: read-only
Description: Cisco UCS equipment:Fan:power managed object property
What is cucsEquipmentFanPower?
This reports the power state of this specific fan, per its power property — essentially whether it's currently powered on. This matters for distinguishing a fan that's spun down or unpowered, perhaps intentionally during a low-load period on a variable-speed design, from one that's powered but mechanically failing. A power state of 'off' on a specific fan slot that should normally be spinning is a distinct condition from a fan that's on but reporting a thermal fault.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.12.1.12 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanPower
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.12.1.12.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanPower.1
Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanPower OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.15 | cucsEquipmentObjects | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.12 | cucsEquipmentFanTable | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.12.1 | cucsEquipmentFanEntry | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.12.1.12 | cucsEquipmentFanPower | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |