CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentFanModuleStatsThresholded

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentFanModuleStatsThresholded

cucsEquipmentFanModuleStatsThresholded

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleStatsThresholded

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.15.1.10

Node type: OBJECT-TYPE

Type: CucsEquipmentFanModuleStatsThresholded

Access: read-only

Description: Cisco UCS equipment:FanModuleStats:thresholded managed object property

What is cucsEquipmentFanModuleStatsThresholded?

This field is a bitmask/enum recording which of the fan module's configured alarm thresholds (upper non-recoverable, upper critical, lower critical, etc.) the current speed reading has crossed. A network admin cares about it because it converts a raw fan RPM number into a severity signal UCS Manager can alert on, telling you whether a slow fan module is merely below normal or already at a critical stall risk. For instance, a value indicating lowerCritical on a fan module would mean that module's fans have dropped far enough to risk inadequate blade cooling.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.15.1.10
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleStatsThresholded

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.15.1.10.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleStatsThresholded.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsEquipmentFanModuleStatsThresholded.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleStatsThresholded OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.15cucsEquipmentFanModuleStatsTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.15.1cucsEquipmentFanModuleStatsEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.15.1.10cucsEquipmentFanModuleStatsThresholdedCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB