CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentFanModuleStatsFanModuleI2CErrorsMax

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentFanModuleStatsFanModuleI2CErrorsMax

cucsEquipmentFanModuleStatsFanModuleI2CErrorsMax

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleStatsFanModuleI2CErrorsMax

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.15.1.17

Node type: OBJECT-TYPE

Type: Unsigned64

Access: read-only

Description: Cisco UCS equipment:FanModuleStats:FanModuleI2CErrorsMax managed object property

What is cucsEquipmentFanModuleStatsFanModuleI2CErrorsMax?

This records the highest I2C error count for the fan module's controller communication seen within the current collection interval, capturing the worst single sample rather than the interval average. It's the number an admin would check first to see whether a fan module's I2C link had a brief severe glitch even if the interval's average looks unremarkable. A max value that spikes to 90 errors in an interval where the average is only 5 suggests one brief but serious communication disruption, such as a jostled connector during a service action.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.15.1.17
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleStatsFanModuleI2CErrorsMax

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.15.1.17.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleStatsFanModuleI2CErrorsMax.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleStatsFanModuleI2CErrorsMax OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.15cucsEquipmentFanModuleStatsTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.15.1cucsEquipmentFanModuleStatsEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.15.1.17cucsEquipmentFanModuleStatsFanModuleI2CErrorsMaxCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB